Chilled Water System

 

Chilled Water System: A Quick Overview A chilled water system is a centralized HVAC setup that produces chilled water at a central plant and distributes it to cooling coils in a building to provide air conditioning. It’s widely used in large offices, hospitals, campuses, and data centers because it can efficiently deliver precise cooling and humidity control. How it works - The chiller removes heat from water using a refrigeration cycle. The resulting chilled water is pumped through a network of pipes to air handling units (AHUs) or fan coils throughout the building. - Inside each AHU, the chilled water runs through a cooling coil. As indoor air passes over the coil, heat is absorbed by the water, cooling the air that is then circulated back into the space. - The warmed water returns to the chiller to be cooled again. The heat removed from the building is ultimately rejected to the outside environment by a cooling source, such as a cooling tower (for water-cooled systems) or an air-cooled condenser (for air-cooled systems). Key components - Chiller: the central machine that provides chilled water. Types include centrifugal, screw, and reciprocating. - Cooling source: a cooling tower for water-cooled systems or an air-cooled condenser for air-cooled systems. - Pumps: primary and secondary (or variable-speed) pumps that move water through the system. - Piping and headers: primary-secondary configurations, two-pipe or four-pipe layouts to deliver chilled water where needed. - Air handling units and terminal devices: coils and controllers that condition indoor air. - Expansion devices and control valves: manage water temperature and flow to match cooling loads. - Controls and sensors: building management systems (BMS) that regulate temperatures, flow, and energy use. - Water treatment: chemicals and systems to prevent corrosion, scaling, and microbial growth in the closed loop. Design and control considerations - System configurations: 2-pipe or 4-pipe systems, primary-only or primary-secondary designs. Central plants may serve multiple zones with decoupled flow for better control. - Water temperatures and delta T: typical supply water is in the range of about 6–12°C (43–54°F), with a common coil delta T of around 4–8°C depending on design. Reset strategies can adjust supply temperature based on outdoor conditions to save energy. - Control strategies: zone-level control with thermostats or sensors, variable-speed drives on pumps and chillers, and advanced controls in a BMS to optimize efficiency and comfort. - Energy efficiency: multiple chillers with staged operation, free cooling when outdoor conditions are suitable, condenser water reset, and high-efficiency pumps. Advantages and applications - Centralized cooling for large spaces: easy to scale and maintain, with consistent comfort and humidity control. - Efficient part-load performance: multiple chillers or modulating chillers can match varying building loads. - Flexible distribution: can serve many zones with different cooling needs through a well-designed piping and control strategy. - Common applications: commercial office buildings, universities and campuses, hospitals, data centers, and large retail or mixed-use developments. Maintenance and upkeep - Water quality: ongoing water treatment to prevent corrosion, scaling, and microbial growth. - Equipment checks: regular inspection of chillers, cooling towers or condensers, pumps, valves, and sensors. - Leak detection and insulation: monitor piping for leaks and maintain insulation to minimize energy losses. - System balancing: ensure proper flow to all zones to avoid over- or under-cooled areas. - Regular testing: verify refrigerant charge, temperature setpoints, and control sequences; calibrate sensors and maintain the performance of the BMS. A chilled water system offers reliable, scalable cooling for large buildings with strong energy-management potential. Proper design, control, and maintenance are key to achieving comfort, efficiency, and long-term performance. If you’d like, I can tailor this into a shorter summary or expand any section for a particular building type or application.

 

Chilled Water System

We are a consulting and contracting company in the same group, For pricing or design download our app, For any purchasing please contact us ASAP 

 
 
 
 

 

All designs are according to NFPA

© 2020 All Rights Reserved

Engineering & Safety Consulting Company Saudi Arabia
Saif – Engineering & Safety Consulting

Integrated Engineering & Safety Consulting Services

We are a specialized engineering consulting firm delivering comprehensive architectural, structural, mechanical, electrical, fire protection, industrial, oil & gas, and environmental engineering services. All designs, studies, and reports are prepared in full compliance with SBC, NFPA, FIDIC, API, ISO, and Saudi Civil Defense & MODON requirements.

🔧 1. General Engineering Consulting

  • FIDIC Contract Administration & Claims Management
  • Engineering Feasibility Studies & Technical Due Diligence
  • Project Management & Technical Supervision
  • Engineering Risk Analysis for Mega & Industrial Projects

🏗️ 2. Civil & Structural Engineering Consulting

  • Structural design of reinforced concrete & steel buildings
  • High-rise towers, bridges, tunnels, and road structures
  • Geotechnical & soil investigation studies
  • Seismic, wind & load analysis (ETABS / SAFE)
  • Structural assessment & retrofit of existing buildings

📐 3. Architectural Design & Urban Planning

  • Residential, commercial & mixed-use architectural design
  • Façade engineering & sustainable green architecture
  • Urban planning & master planning services
  • BIM modeling & coordination (Revit Architecture)

⚙️ 4. Mechanical Engineering Consulting

  • HVAC systems design & energy optimization
  • Water supply, drainage & plumbing systems
  • Pumping stations, compressors & industrial cooling
  • Fuel systems: Diesel, LPG & Natural Gas
  • Industrial mechanical & process systems

⚡ 5. Electrical Engineering Consulting

  • Low & Medium Voltage (LV/MV) power systems
  • Load calculations, voltage drop & short-circuit studies
  • Solar PV & renewable energy systems
  • Low current & ELV systems design
  • BMS, SCADA, CCTV & Access Control Systems

🔥 6. Fire Protection & Life Safety Engineering

This is our core specialty. All fire protection designs, reports, and approvals are delivered in strict compliance with SBC, NFPA, Saudi Civil Defense, and MODON regulations.

🔴 Firefighting Systems Design

  • Wet, Dry, Pre-Action & Deluge Sprinkler Systems
  • Foam systems, foam monitors & foam standpipes
  • Water Mist systems (NFPA / UL / FM)
  • Fire pump room & hydraulic calculations
  • ESFR, CMSA, CMDA & In-Rack Sprinklers

🔔 Fire Alarm & Detection Systems

  • Addressable, Conventional & Voice Evacuation
  • VESDA, Linear Heat & Video Smoke Detection
  • Smart & IoT-enabled fire detection systems

📄 Fire Safety Studies & Reports

  • Fire Strategy Reports
  • Fire Risk Assessments
  • CFD Smoke & Evacuation Analysis
  • SBC, NFPA & MODON compliance reports
  • Emergency & Evacuation Plans

🏭 7. Industrial Engineering Consulting

  • Factory layout & material flow optimization
  • Production line improvement & lean manufacturing
  • OEE, time & motion studies
  • Industrial piping & process engineering

🛢️ 8. Oil & Gas Engineering Consulting

  • API 650 & API 620 storage tank design
  • LPG, LNG & Natural Gas piping systems
  • Explosion risk & ATEX hazard studies

🌿 9. Environmental Engineering Consulting

  • Environmental Impact Assessments (EIA)
  • Air quality & emission monitoring
  • Waste & hazardous waste management
  • STP, WWTP & grey water systems

📞 Contact Us for Engineering Proposals

WhatsApp / Call: 0557984942

WhatsApp / Call: 0545587404

Email: project.manager@telal-elwatan.com

لقسم الاستشارات الهندسية والتقارير والشهادات ومتطلبات الدفاع المدنى والبلدية و هيئة مدن  يرجى الاتصال على 0557984942

للتوريدات والطلبات الاخرى يرجى ارسال طلبك واتس اب لخدمتكم

بشكل اسرع على احد الارقام التالية 0531433890 

X