Fresh Air Systems Control

كل تصميماتنا مطابقة للكود السعودى والدولى

معتمدين من بلدى

معتمدين من امانة الرياض

معتمدين من هيئة مدن

معتمدين من الدفاع المدنى

Learn about the importance of contracting with an accredited engineering consultancy, the conditions and requirements involved, and how to choose the best engineering offices to manage and design your projects effectively and efficiently.
Contact us now or reach us on WhatsApp at the following number:
0557984942

© 2012 All Rights Reserved

Fresh Air Systems Control

 

Fresh Air Systems Control Fresh air systems bring outdoor air into indoor spaces to maintain good air quality, but simply opening a damper isn’t enough. Effective control ensures occupants breathe clean air while energy use stays reasonable. Here’s a compact guide to how fresh air systems are controlled in modern buildings. What is a fresh air system and why control matters - Purpose: Supply outdoor air to dilute indoor pollutants, control humidity, and maintain comfort. - Challenge: Outdoor air often requires conditioning (cooling/heating and dehumidification), so uncontrolled introduction can waste energy. - Goal: Balance IAQ with energy efficiency by adjusting how much outdoor air enters the system based on occupancy, air quality, and environmental conditions. Key control strategies 1) Economizers and outdoor air dampers - Economizer modes use outdoor conditions to reduce mechanical cooling or heating when outdoor air is already suitable. - Dampers modulate to bring in more outdoor air during mild weather and restrict it when outdoor conditions are extreme. - Benefit: Energy savings by leveraging favorable outdoor air while still maintaining IAQ. 2) Demand-Controlled Ventilation (DCV) - Uses sensors (CO2, occupancy, or ventilation index) to adjust ventilation rates in real time. - CO2-based DCV interprets higher CO2 as more occupants and increases fresh air accordingly; as people leave, ventilation can be reduced. - Occupancy-based DCV uses presence detectors to scale air intake with actual use. - Benefit: Maintains IAQ with lower energy use in spaces that aren’t always full. 3) Energy recovery and air handling integration - Energy recovery devices (enthalpy wheels, heat exchangers, or run-around loops) recover cooling/heating and sometimes humidity from exhaust air to pre-condition incoming outdoor air. - This reduces the peak energy required to condition fresh air. - Integration with the main AHU (air handling unit) or dedicated fresh air units ensures coordinated control of temperature, humidity, and ventilation rate. 4) Temperature and humidity control - Outdoor air must be conditioned before mixing with return air. Controllers manage outdoor air fraction so indoor temperature and humidity stay within setpoints. - In humid climates, more conditioning is needed, so control strategies may restrict outdoor air during high humidity periods or rely more on dehumidification. - In milder climates, a larger outdoor air fraction can be used with minimal energy impact. Sensors and data to support control - Core sensors: CO2 (or occupancy), temperature, humidity, outdoor air temperature, and sometimes pressure to balance ductwork. - Best practices: - Place CO2/occupancy sensors where air is well mixed and representative of occupant breathing zones. - Calibrate and maintain sensors regularly; drift can lead to oversized or undersized ventilation. - Use a centralized controller or building management system (BMS) to coordinate damper positions, fans, and energy recovery devices. Design and operation tips - Start with a clear IAQ target: define acceptable CO2 levels, humidity range, and comfort temperatures. - Set reasonable outdoor air limits: allow sufficient air for IAQ, but don’t over-ventilate to avoid unnecessary conditioning loads. - Use DCV for spaces with fluctuating occupancy (e.g., conference rooms, classrooms, lobbies) to save energy without sacrificing air quality. - Pair fresh air control with mechanical zoning: different areas may require different ventilation rates and schedules. - Regular maintenance matters: inspect dampers for smooth operation, clean or replace filters, and verify sensor accuracy. - Test and tune: perform commissioning to validate control responses to occupancy changes, outdoor conditions, and setpoints. Common issues and quick fixes - Sensor drift or placement issues causing stale or excessive ventilation: recalibrate sensors and relocate if necessary. - Damper seizing or slow response: perform motor and linkage maintenance; ensure control signals are clean and undisturbed. - Mismatched airflows across zones: balance ducts and verify pressure relationships to prevent short-circuiting of outdoor air. - Over-ventilation in unoccupied periods: adjust DCV setpoints or occupancy schedules to avoid energy waste. A practical example An office suite uses a ceiling-mounted AHU with an energy recovery wheel, a CO2 sensor in each open-plan area, and a programmable controller. During peak occupancy, CO2 rises and the controller increases outdoor air flow, while the energy recovery wheel preconditions the incoming air. In late afternoon when occupancy drops, the DCV reduces fresh air to save energy, yet CO2 remains below the target due to adequate airflow in the remaining occupants. The result is comfortable conditions and efficient operation. Conclusion Fresh air systems control is about intelligent, responsive ventilation that protects indoor air quality without draining energy. By combining economizers, demand-controlled ventilation, energy recovery, and robust sensing with careful design and ongoing maintenance, buildings can deliver healthy environments and sustainable performance. If you’d like, I can tailor this to a specific setting (office, school, hospital, or apartment), provide a shorter version for a brochure, or expand on any particular control strategy.

 

Fresh Air Systems Control

We are a consulting and contracting company in the same group, For pricing or design download our app, For any purchasing please contact us ASAP 

 
 
 
 

 

All designs are according to NFPA

© 2020 All Rights Reserved

Engineering & Safety Consulting Company Saudi Arabia
Saif – Engineering & Safety Consulting

Integrated Engineering & Safety Consulting Services

We are a specialized engineering consulting firm delivering comprehensive architectural, structural, mechanical, electrical, fire protection, industrial, oil & gas, and environmental engineering services. All designs, studies, and reports are prepared in full compliance with SBC, NFPA, FIDIC, API, ISO, and Saudi Civil Defense & MODON requirements.

🔧 1. General Engineering Consulting

  • FIDIC Contract Administration & Claims Management
  • Engineering Feasibility Studies & Technical Due Diligence
  • Project Management & Technical Supervision
  • Engineering Risk Analysis for Mega & Industrial Projects

🏗️ 2. Civil & Structural Engineering Consulting

  • Structural design of reinforced concrete & steel buildings
  • High-rise towers, bridges, tunnels, and road structures
  • Geotechnical & soil investigation studies
  • Seismic, wind & load analysis (ETABS / SAFE)
  • Structural assessment & retrofit of existing buildings

📐 3. Architectural Design & Urban Planning

  • Residential, commercial & mixed-use architectural design
  • Façade engineering & sustainable green architecture
  • Urban planning & master planning services
  • BIM modeling & coordination (Revit Architecture)

⚙️ 4. Mechanical Engineering Consulting

  • HVAC systems design & energy optimization
  • Water supply, drainage & plumbing systems
  • Pumping stations, compressors & industrial cooling
  • Fuel systems: Diesel, LPG & Natural Gas
  • Industrial mechanical & process systems

⚡ 5. Electrical Engineering Consulting

  • Low & Medium Voltage (LV/MV) power systems
  • Load calculations, voltage drop & short-circuit studies
  • Solar PV & renewable energy systems
  • Low current & ELV systems design
  • BMS, SCADA, CCTV & Access Control Systems

🔥 6. Fire Protection & Life Safety Engineering

This is our core specialty. All fire protection designs, reports, and approvals are delivered in strict compliance with SBC, NFPA, Saudi Civil Defense, and MODON regulations.

🔴 Firefighting Systems Design

  • Wet, Dry, Pre-Action & Deluge Sprinkler Systems
  • Foam systems, foam monitors & foam standpipes
  • Water Mist systems (NFPA / UL / FM)
  • Fire pump room & hydraulic calculations
  • ESFR, CMSA, CMDA & In-Rack Sprinklers

🔔 Fire Alarm & Detection Systems

  • Addressable, Conventional & Voice Evacuation
  • VESDA, Linear Heat & Video Smoke Detection
  • Smart & IoT-enabled fire detection systems

📄 Fire Safety Studies & Reports

  • Fire Strategy Reports
  • Fire Risk Assessments
  • CFD Smoke & Evacuation Analysis
  • SBC, NFPA & MODON compliance reports
  • Emergency & Evacuation Plans

🏭 7. Industrial Engineering Consulting

  • Factory layout & material flow optimization
  • Production line improvement & lean manufacturing
  • OEE, time & motion studies
  • Industrial piping & process engineering

🛢️ 8. Oil & Gas Engineering Consulting

  • API 650 & API 620 storage tank design
  • LPG, LNG & Natural Gas piping systems
  • Explosion risk & ATEX hazard studies

🌿 9. Environmental Engineering Consulting

  • Environmental Impact Assessments (EIA)
  • Air quality & emission monitoring
  • Waste & hazardous waste management
  • STP, WWTP & grey water systems

📞 Contact Us for Engineering Proposals

WhatsApp / Call: 0557984942

WhatsApp / Call: 0545587404

Email: project.manager@telal-elwatan.com

لقسم الاستشارات الهندسية والتقارير والشهادات ومتطلبات الدفاع المدنى والبلدية و هيئة مدن  يرجى الاتصال على 0557984942

للتوريدات والطلبات الاخرى يرجى ارسال طلبك واتس اب لخدمتكم

بشكل اسرع على احد الارقام التالية 0531433890 

X